Next: 6.1.2 Connecting runner seqments
Up: 6.1 Introduction
Previous: 6.1 Introduction
Suppose that we have n sections with n gates.
We know that volume to be delivered at gate i and is denoted by .
The gate velocity has to be in a known range.
The filling time has to be in a known function and we recomend to use
Eckert/Bar-Meir's formula.
For this discussion it is assumed that the filling has to be in known
range and the flow rate can be calculated by
Thus, gate area for the section
Armed with this knowledge, one can start design the runner system.
To vent in the picture.
To put ref to the picture
= 0.3
Figure:
A geometry of runner connection
|
Genick Bar-Meir ||| www.potto.org
copyright Dec , 2006
The pdf version is also available here